5103

                                                                                                                       Revised 1/03

 

RESPIRATORY PROTECTION

 

PURPOSE

 

To establish a respiratory protection program which coordinates the selection, use and maintenance of respiratory protection.

 

In the control of occupational diseases and discomfort caused by breathing air that is contaminated with potentially harmful dusts, fumes, sprays, mists, fogs, smokes, vapors, or gases, the primary objective shall be to minimize workplace contamination. This shall be accomplished as far as feasible by accepted engineering control measures. When effective engineering controls are not feasible, or while they are being implemented or evaluated and the potential for overexposure exists, appropriate respirators shall be used.

 

SCOPE

 

All Fermilab divisions and sections.

 

DEFINITIONS

 

Airline respirator – An atmosphere-supplying respirator for which the source of breathing air is not designed to be carried by the user.

 

Air-purifying respirator – A respirator with an air-purifying filter, cartridge, or canister that removes specific air contaminants by passing ambient air through the air-purifying element.

 

Assigned protection factor - The expected workplace level of respiratory protection that would be provided by a properly functioning respirator or a class of respirators to properly fitted and trained users.  NIOSH protection factors will be used until OSHA publishes its own values.

 

Atmosphere-supplying respirator – A respirator that supplies the respirator user with breathing air from a source independent of the ambient atmosphere, and includes air-line respirators (ALR) and self-contained breathing apparatus (SCBA) units.

 

Ceiling – The concentration that should not be exceeded during any part of the working exposure.

 

Certified - Evaluated and listed as permissible by the National Institute for Occupational Safety and Health (NIOSH), the Mine Safety and Health Administration (MSHA), or the Bureau of Mines (BM).

 

Demand respirator – An atmosphere-supplying respirator that admits breathing air to the facepiece only when a negative pressure is created inside the facepiece by inhalation.

 

Disposable respirator - See Filtering facepiece.

 

End-of-service-life indicator (ESLI) – A system that warns the respirator user of the approach of the end of adequate respiratory protection, for example that the sorbent is approaching saturation or is no longer effective.

 

Escape-only respirator - A respirator intended only for use during emergency egress from a hazardous atmosphere.

 

Fermilab prescribed exposure limit (FPEL) - The maximum allowable concentration of a contaminant in air which an individual may be exposed. These may be time weighted averages, short term limits, or ceiling limits. The prescribed exposure limit for a particular chemical is the lowest published value from ACGIH or OSHA.

 

Filtering facepiece – (dust mask) – means a negative pressure particulate respirator with a filter as an integral part of the facepiece or with the entire facepiece composed of the filtering medium.  A respirator which maintenance is not intended, but discarded after a single use.

 

Fit factor – A quantitative estimate of the fit of a particular respirator to a specific individual, and typically estimates the ratio of the concentration of a substance in ambient air to its concentration inside the respirator when worn.

 

Fit test – The protocol to qualitatively or quantitatively evaluate the fit of a respirator on an individual.  (See also Qualitative Fit Test and Quantitative Fit Test).

 

Hazardous atmosphere - An atmosphere that contains a contaminant(s) in excess of the exposure limit or that is oxygen deficient.

 

Helmet – A rigid respiratory inlet covering that also provides head protection against impact and penetration.

 

Hood – A respiratory inlet covering that completely covers the head and neck and may also cover portions of the shoulders and torso.

 

Immediately dangerous to life or health (IDLH) – An atmosphere that poses an immediate threat to life, would cause irreversible adverse health effects, or would impair an individual’s ability to escape from a dangerous atmosphere.

 

Loose-fitting facepiece - A respiratory inlet covering that is designed to form a partial seal with the face.  Types include helmet and hood.

 

Negative pressure respirator (tight fitting) – A respirator in which the air pressure inside the facepiece is negative during inhalation with respect to the ambient air pressure outside the respirator.

 

Non-required respirator user – A Universities Research Association (URA) employee who, wears a respirator however, does not have the potential to be overexposed to a hazardous atmosphere.

 

Oxygen deficient atmosphere – An atmosphere with an oxygen content below 19.5% by volume.

 

Physician or other licensed health care professional (PLHCP) – An individual whose legally permitted scope of practice (i.e., license, registration, or certification) allows him or her to independently provide, or be delegated the responsibility to provide, some or all of the health care services required within this document.

 

Powered air-purifying respirator - An air-purifying respirator that uses a blower to force the ambient atmosphere through air-purifying elements to the inlet covering.

 

Positive pressure respirator – A respirator in which the pressure inside the respiratory inlet covering exceeds the ambient air pressure outside the respirator.  Examples include Airline respirators and Self-contained breathing apparatus.

 

Pressure demand respirator – A positive pressure atmosphere-supplying respirator that admits breathing air to the facepiece when the positive pressure is reduced inside the facepiece by inhalation.

 

Qualitative fit test - A pass/fail fit test that is used to assess the adequacy of respirator fit, and that relies on the individual’s response to the test agent.

 

Quantitative fit test – An assessment of the adequacy of respirator fit by numerically measuring the amount of leakage into the respirator.  (See also Fit factor).

 

Respirator Program Report – A respirator qualification matrix located on the ES&H Section web page which indicates the status of all respirator required users at Fermilab.

 

Respirator required user – A Universities Research Association (URA) employee who has the potential to be overexposed to a hazardous atmosphere, and is included in the Fermilab Respirator Program.

 

Reusable respirator - See Tight-fitting facepiece.

 

Self-contained breathing apparatus (SCBA) – An atmosphere-supplying respirator for which the breathing air source is designated to be carried by the user.

 

Short-Term Exposure Limit (STEL) – Typically considered to be a 15-minute TWA exposure which should not be exceeded at any time during a workday even if the

8-hour Time-Weighted Average is within the appropriate exposure limits.

 

Tight-fitting facepiece – A respiratory inlet covering that is designed to form a complete seal with the face. A respirator for which maintenance is required and that is designed for repeated use.

 

Time-Weighted Average (TWA) – The time-weighted average concentration for a conventional 8-hour workday and a 40-hour workweek.

 

User seal check – An action conducted by the respirator user to determine if the respirator is properly seated to the face.

 

RESPONSIBILITIES

 

ES&H Section:

 

1.      The responsibility and authority for the respirator program shall be assigned to a single individual in the Health and Safety Group of the ES&H Section titled the Respirator Program Administrator.

 

2.      Update program, as necessary, to comply with OSHA and DOT regulations, ANSI and NIOSH standards, and ACGIH Threshold Limit Values.

 

3.      Annually review the respiratory protection program to determine its effectiveness.  This is accomplished through a periodic review of the chapter, periodic reviews of the Respirator Program Report on the ESH Webpage, distribution of the Industrial Hygiene Training Past Due Assessment, Division and Section tripartite reviews, discussions with employees and supervisors during required annual training and fit-testing campaigns, and the sharing and discussing of respirator related information at the monthly Industrial Hygiene Subcommittee meetings.  Any necessary changes to the programs will be made when they become apparent.

 

4.      Maintain and provide training in the use of quantitative fit testing equipment.

5.      Stock supply of NIOSH approved disposable and reusable air-purifying respirators.

 

6.      Develop lesson plans for employee training in the use of respiratory protection.  Provide training upon request.

 

7.            Maintain Respirator Program Report database.

 

8.            Investigates malfunctions of respiratory protection equipment to determine cause and assure corrective measures are taken.

 

9.            Develop cartridge change out schedules for exposures to chemicals. If the cartridge does not have an end of service life indicator (ESLI), the Respirator Program Administrator is to consult with the manufacturer to determine an appropriate change schedule.

 

Division/Section ES&H Groups:

 

1.            Evaluate work area and recommend procedures to maintain personal exposure below Fermilab prescribed exposure limits.

 

2.      Assess the need for respiratory protection.  If respirator protection is required, complete the Medical Surveillance Request for Respiratory Protection Usage Form (See page 22) and send to the Medical Department.

 

3.      Ensure that employees have received medical approval before reusable respiratory protection is issued.

 

4.            Provide employees training in the use of reusable respiratory protection.  Enter all training records into TRAIN.

 

5.            Conduct quantitative fit testing, as needed, for employees issued reusable, tight fitting respiratory protection.   Send all fit testing records to the ES&H Section’s Respirator Program Administrator for entry into the Respirator Program Report database.

 

6.            Select and issue the correct type of respirator.  Contact the ES&H Section to help develop a cartridge change schedule if chemicals are involved.

 

7.            The ES&H Section may provide the above duties for those divisions and sections that do not have ES&H personnel knowledgeable in the area of respiratory protection.

 

 

Supervision:

 

1.      Ensure respirators are used in accordance with instructions and training received.

 

2.      Ensure respirators are cleaned, disinfected and stored in a clean, sanitary condition.

 

3.            Ensure respirators are in good working condition.

4.            Notify Division/Section Senior Safety Officer (SSO) of any changes in personnel enrolled in the program and any changes in working conditions that may change workers' need for respirator protection. The employee’s Individual Training Needs Assessment (ITNA) shall be revised as well.

 

Employees:

 

1.      Use respirators in accordance with instructions and training received.

 

2.      Maintain, clean, inspect, and store respirators as instructed.

 

3.      Report any malfunction of a respirator to supervisor.

 

4.            Immediately discontinue use if respirator malfunctions and immediately go to an area with respirable air.

 

Medical Department:

 

1.      With the aid of OSHA’s respiratory protection standard, 29 CFR 1910.134, medical questionnaire (appendix C) the PLHCP shall determine what health and physical conditions are pertinent for assuring the respirator wearer is capable of performing work while wearing respiratory protection.

 

2.            Conduct medical surveillance of respirator wearers every two years.

 

PROCEDURES

 

1.            Evaluation

 

Ø      Determining Factors

 

Those operations for which respiratory protection is considered, the division/section SSO or designee must determine the nature and degree of hazard posed by the exposure. The selection of the proper type of respirator entails consideration of the following factors:

 

a.      What is the nature of the contaminants?

b.      Are the contaminants dusts, mists, fumes, vapors or gases or combinations?

c.      What are the anticipated exposure concentrations?

d.            What are the permissible exposure limits or TLVs?

e.             Is there a potential for oxygen deficiency?

f.              Does the contaminant have adequate warning properties?

g.      Is there an oil mist present in the work environment?

h.      Could the concentrations be determined to be immediately dangerous to life and health (IDLH)?

i.       Will the contaminant irritate eyes?

j.       Can the contaminant be absorbed through the skin?

k.      How long will the respirator be worn?

l.       What impact will the respirator have on the worker?

m.     What are the assigned protection factors for the respirator?

n.      Does the respirator offer comfort of fit?

o.      What filter efficiency is necessary due to governmental regulation?

p.      Will the use be voluntary or mandatory?

 

Ø      Factor Analyses

 

a.      Nature of the Hazard

 

In selecting a particular respirator, consideration of the process and the materials involved is warranted.  The contaminant’s physical, chemical and toxicological properties are to be investigated and a determination made as to the potential for oxygen deficiency or IDLH atmospheres.

 

b.      Oxygen Deficiency or IDLH Atmospheres

 

   Appropriate respirator selection initially involves a determination as to whether an oxygen deficient atmosphere (less than 19.5% by volume) or an IDLH atmosphere exists or could exist in the area where work is to be performed.  Supplied air full facepiece respirators with escape provisions or self-contained breathing apparatuses (SCBA) must be used.  OSHA has stated that if the concentration is unknown, but the atmosphere is unlikely to be IDLH, the employer may rely on professional judgment, past history and knowledge of the operation to select the proper respirator.

 

c.      Physical and Chemical Properties

 

      This factor involves determining if the contaminants are dusts, mists, fumes, vapors, or gases.  The selection of an air-purifying respirator must also consider the classification of the contaminant into a physical form.  A dust is a solid mechanically produced particle or fiber.  A fume is a condensed solid formed from the melting and vaporization of a metal.  A mist is liquid droplet particles. A vapor is a gas, which evolves from a liquid or a solid at normal conditions.  Gases are formless fluids at normal conditions.  Particulate respirators remove contaminants by filtering the air through a fibrous material.  Vapor and gas respirators remove contaminants by interaction of molecules with a sorbent material.

 

d.      Warning Properties

 

      If a negative pressure respirator is used for protection against a gas or a vapor, the contaminant must have adequate warning properties.  A contaminant having an odor or a threshold of irritation above the FPEL is considered to have poor warning properties.  The following compounds are a partial listing of contaminants that may be present at Fermilab and are considered to have poor warning properties:  carbon monoxide, carbon dioxide, hydrogen sulfide, ozone.  However, if a cartridge has an end of service life indicator or a change schedule has been implemented that is based upon documented service life data, airborne exposures, and duration of exposure, a negative pressure respirator may be used to protect against materials deemed to have poor warning properties. 

 

e.      Permissible Exposure Limits (PEL) and Threshold Limit Valves (TLVs)

 

   In selecting a respirator, an understanding of the permissible exposure limits and threshold limit values as deemed applicable is necessary.  Exposure monitoring data or the results of an exposure assessment are to be used to determine the needed protection factor.  Selection should also consider ceiling limits and short term limits for contaminants having such a designation.

 

f.       Skin Absorption or Eye Irritation

 

   Air contaminants that are eye irritants require the selection of a full facepiece respirator.  Where information exists which indicates the contaminant is capable of being absorbed through the skin and systemic injury or death could result from the exposure, appropriately-selected full body protective equipment used with a self-contained breathing apparatus must be utilized.

 

2.      Selection

 

Types of Respirators

 

The following types of respiratory protective equipment are used at Fermilab:

·        Filtering facepiece – (dust masks)

·        Half mask air-purifying respirator

·        Full face air-purifying respirator

·        Powered air-purifying respirator (loose-fitting and tight-fitting)

·        Airline respirator (loose-fitting)

·        Escape-only air-supplied respirator

·        Self-Contained Breathing Apparatus (pressure demand)

 

 

a.      Particulate Filter

 

   A particulate (mechanical) filter respirator is designed to give protection against particle air contaminants, such as non-volatile dusts, mists or metal fumes.  The items to be concerned with in the selection of this type of respirator are:  (1) resistance to breathing caused by the filtering element; (2) the fit of the facepiece to various sizes and shapes of faces; (3) the presence of oil mists; and (4) the necessary filtering efficiency.  This type of respirator device does not offer protection against oxygen deficiency, carbon monoxide, gases, or vapors.  Specifically, adaptable particulate filters are available for usage with chemical cartridge respirators where suspected air contaminants require a multiple purpose type respirator.  The program administrator should consult with the manufacturer or refer to the manufacturer’s technical bulletin when selecting filter medium or cartridges.

 

   Particulate respirators are classified into the categories as follows:

 

Filter

Filter Type

Efficiency

(No Oil)

N100

N99

N95

99.97

99

95

(Oil Resistant)

R100

R99

R95

99.97

99

95

(Oil Proof)

P100

P99

P95

99.97

99

95

 

   The NIOSH service time recommendations for filter replacement is as follows:

 

  

All Filters:  The service life of all filters is limited by considerations of hygiene, damage and breathing resistance.

 

   N Series:  Can be used and reused subject to considerations of hygiene, damage and increased breathing resistance.  However, for dirty workplaces that could result in high filter loading, i.e., 200 mg, service time should only be extended beyond 8 hours of use continuous or intermittent by performing an evaluation that demonstrates that the extended use will not degrade the filter efficiency below the specified level or that the total mass loading on the filter is less than 200 mg. 

 

   R Series:  Should only be used for a single shift or for 8 hours of continuous or intermittent use when oil is present.  However, service time for R series filters can be extended using the methods described above for N filters.

 

   P Series:  Should be used and reused in accordance with the manufacturer’s time use limitation recommendations when oils are present.  P series can be used and reused subject only to considerations of hygiene, damage and increased breathing resistance if oil aerosols are not present.

 

Under 42 CFR Part 84, certified particulate filters can be used without regard to aerosol size because filter testing is done with the most penetrating particle size.  According to NIOSH, all filters certified will be effective against any aerosol.  Therefore, the consideration of filter efficiency is not workplace dependent and the need for higher efficiency filters is primarily dictated by government regulations, e.g., lead, asbestos.

 

b.      Chemical Cartridge Respirator

 

   Chemical cartridge respirators normally consist of a facepiece (half-face - mouth and nose or full-face - mouth, nose and eyes) connected directly to two cartridges containing chemicals.  Various chemicals are used in the cartridges and each chemical is specific as to which air contaminant will be removed.  Chemical cartridge respirator usage is for non-emergency situations and is not to be used for atmospheres which are immediately hazardous to life or health, nor is it to be used in oxygen deficient atmospheres.  Although NIOSH approves chemical cartridges according to 10 classifications, the selection can be narrowed into seven categories because most manufacturers offer dual-purpose cartridges.  The categories are as follows:

 

 

1)      organic vapors - black

2)      ammonia, methylamine - green

3)      formaldehyde, HF- olive green

4)      acid gases (S02,H2S, HC1, Cl) - white

5)      organic vapor/acid gas - yellow

6)      paint spray

7)      pesticide

 

   The Respirator Program Administrator should review the manufacturer's technical bulletin to determine the appropriate cartridge or cartridges.  In addition, the limitations of each cartridge with respect to maximum concentrations must be considered in the selection process.  If the cartridge does not have an end of service life indicator (ESLI), the Program Administrator is to consult with the manufacturer to determine an appropriate change schedule. A generalized rule of thumb for estimating organic vapor service life can be used.  If a chemical has a boiling point of greater than 70 °C and the concentration is less than 200 ppm, a service life of 8 hours under normal work rates is expected.  Reducing the concentration by a factor of ten will increase the service life by a factor of five.  Humidity above 85% will reduce service life by 50%.

 

c.      Air-Line Respirator

 

The only air-line respirator at Fermilab is an abrasive-blasting unit located within the Technical Division at Industrial Building 2.  The air-line respirator is connected to a suitable breathing air source by a hose which delivers the breathable air to the user continuously in sufficient volume to meet breathing requirements.  The loose-fitting helmet provides full-face (mouth, nose and eye) coverage.

 

Note:    Airline respirators without escape capabilities are only to be used in atmospheres where air contaminant concentrations are not IDLH.  This limitation is necessary because the air supply is solely dependent upon an outside source, which is not readily available to the wearer.

 

The compressor is located and constructed to avoid entry of contaminated air.  The air system is equipped with filters, sorbent beds and alarm systems as necessary to ensure Grade D breathing air is supplied.  The oil lubricated compressor is equipped with a carbon monoxide alarm which monitors the air to prevent the carbon monoxide in the breathing air from exceeding 10 ppm.  The air is dried.  This fixed system is equipped with a compressor capable of supplying air at 110-115 psig at the outlet of the purification system.  The system is equipped with a low pressure alarm when buffer tank pressure drops below 85 psig.

d.      Self-Contained Breathing Apparatus

 

   A self-contained breathing apparatus (SCBA) provides 15 to 60 minutes of breathable air from a self-contained cylinder.  For this reason, it is ideally suited for emergency rescue operations but the limitations on air supply makes it a less desirable source of air for normal work operations of extended duration.

   The Fire Department uses an Eagle air compressor (not oil lubricated) to fill a 4-cylinder (6000 psi each) cascade unit.  This cascade unit is used to fill the numerous 2216 SCBA cylinders and the four (4) 4500 SCBA cylinders. Only pressure demand SCBA respirators are used at Fermilab.  In addition, a remote filling hose rated at 10,000 psi is used to link the compressor filling station to the two ASME 5500-6000 psi cylinders on board the 701 Rescue Truck and to perform any remote filling of cylinders at the emergency scene. 

 

The Fire Department has a service contract to test the air quality of the compressor unit on a quarterly basis.  The compressor itself is serviced annually (i.e., sorbent bed and filter changes) by the factory authorized service technician per manufacturer's specifications.  The cylinders are hydrotested as required.  The SCBAs are checked daily, and thoroughly inspected monthly by Fire Department personnel.  The SCBAs are flow tested and calibrated annually by a factory authorized service contractor.  All records are kept on file at the Fire Department.

 

e.             Emergency Escape Respirators

 

Emergency escape respirators are used for emergency escape from oxygen deficient hazard (ODH) areas in the Beams Division.  The emergency escape units provide a 5‑minute supply of air and are require to be brought into areas that are ODH class 1-4.  These units are only permitted for escape purposes and are not to be used for entry into an IDLH atmosphere under any circumstances. The 5-minute escape packs are inspected on a monthly basis by members of the Beams Division ES&H Group.  The 5-minute escape pack plastic hoods are checked for cracks and discoloration and the gauges are checked for pressure.  See Chapter 5064 for more information on the Fermilab ODH Program

 

f.       Assigned Protection Factor (APF)

 

            The APF is used to select the appropriate respirator.  The APF is the expected workplace level of respiratory protection that would be provided by a properly functioning respirator or a class of respirators to properly fitted and trained users.

The NIOSH assigned protection factors are as follows:

 

 

Respirator Type

 

NIOSH Respirator Decision Logic

 

 

Particulate Hazards

 

Gas/Vapor Hazards

Combination Gas/Vapor & Particulate Hazards

Single-use or quarter mask

5

N/A

N/A

APR half mask except single-use

10

10

10

APR full facepiece

10

50

10

ALR half mask, demand

10

10

10

ALR full facepiece, demand

50

50

50

ALR hood or helmet, loose-fitting, continuous

25

25

25

ALR hood or helmet, tight-fitting, continuous

25

25

25

ALR half mask, continuous

50

50

50

ALR full facepiece, continuous

50

50

50

PAPR hood or helmet, loose-fitting*

25

25

25

PAPR hood or helmet, tight-fitting*

25

25

25

PAPR half mask

50

50

50

PAPR full facepiece

50

50

50

SCBA full facepiece, demand

50

50

50

ALR half mask, pressure demand

1,000

1,000

1,000

ALR full facepiece, pressure demand

2,000

2,000

2,000

SCBA full facepiece, pressure demand

10,000

10,000

10,000

ALR full facepiece, demand/SCBA, pressure demand

10,000

10,000

10,000

Notes:

*NIOSH does not differentiate between loose- and tight-fitting hoods and helmets.

 

ALR = Airline Respirator

APR = Air Purifying Respirator

PAPR = Powered Air Purifying Respirator

SCBA = Self Contained Breathing Apparatus

 

3.      Issuance

 

a.      Only knowledgeable ES&H personnel are permitted to select and issue respiratory protection.  Guidelines such as ANSI Z88.2 -1994, the NIOSH Selection Guide, applicable OSHA regulations, or other reputable source should be used as an aid in the selection process.

 

b.            Before a reusable respirator is issued, the individual must receive clearance from the Medical Department.  This includes non-required respirator usage.

c.      Tight-fitting respirators shall not be issued to required respirator users if facial hair comes between the sealing surface of the facepiece and the face or if facial hair interferes with valve function.

 

d.      Disposable respirators may be used ONLY when the estimated exposure level is less than half of the Fermilab prescribed exposure limit.

 

e.      Fit testing must be performed for all respirator-required users.  NOTE:  Emergency escape-only air-supplied respirators and filtering facepieces worn for personal comfort (voluntary use), are excluded from this requirement.

 

f.              Records that document fit testing and issuance must be submitted to the ES&H Section for inclusion into the Respirator Program Report database. These forms are contained in the ES&H Section IH Manual (Chapter 5.1).

 

g.      Issuance of respirators, including disposables, shall be documented.  The issuance of disposables or non-required tight-fitting respirators shall be recorded on the Respirator Log Sheet form (See page 23).  The Respirator Log Sheet shall be maintained by the ES&H Section’s Health and Safety Group and kept where the respirators are stored.  Employees will be given a copy of Appendix D of the OSHA standard 1910.134 (See page 24).  The Respirator Program Report on the ESH Train Web-page serves as the required reusable respirator user issuance record (Exception – Beams Division Operators are not provided with their own SCBA masks).

 

4.      Medical Qualification

 

Persons shall not be issued a reusable respirator until it has been determined by the Fermilab Physician or Licensed Health Care Provider that they are physically and psychologically able to wear a respirator under working conditions as specified by OSHA CFR 1910.134.  The D/S ES&H Group issuing the respirator must provide the physician with meaningful work-related information to assist in the evaluation (i.e., the Medical Surveillance Request for Respiratory Protection Usage form, page 22).  The medical evaluation shall be repeated every two years.

For disposable respirators, the person issuing the respirator shall ask the employee if they have any medical conditions that may prohibit their use of the respirator.   If there is, the person shall be referred to the Medical Department before the respirator is issued.  The log shall indicate if a referral was necessary.

 

5.      Training

 

Required and non-required reusable respirator wearers shall be given adequate training to ensure proper respirators use.  Training shall be documented per procedures in ES&H Manual Chapter 4010.

a.      Respirator wearers must receive training on the following:

 

-        Instruction on the nature of the respiratory hazard.

 

-        The proper selection, use, and maintenance of respirators.

 

-        The limitations of the respirator.

 

-               The proper way to wear and fit the respirator.

 

-        The procedures to perform positive and negative seal checks.  Employees will be given a copy of Appendix B-1 of the OSHA standard 1910.134 (See page 25).

 

-               The employee shall be given the opportunity to handle the respirator, learn how to wear, adjust, clean, store and test it for a proper fit before each wearing.  Employees will be given a copy of Appendix B-2 of the OSHA standard 1910.134 (See page 26).

 

-               Required respirator wearers shall be trained annually.

 

b.      Supervisors of reusable respirator wearers shall receive initial training on the proper use of respirators.  The training shall include as a minimum:

 

-        Basic respiratory protection practices (see above).

 

-        Nature and extent of respiratory hazards to which persons under his/her supervision may be exposed.

 

-        Recognition and resolution of respirator problems.

 

-        Basic elements of the respirator program.

 

c.             The ES&H Section will provide lesson plans for training.

 

6.      Fit Testing

 

a.      Quantitative fit testing must be completed for all tight-fitting, required respirator users.  This includes all negative pressure air-purifying respirators, powered air-purifying respirators, and self-contained breathing apparatus. Positive pressure respirators with a tight seal to the face shall be fit tested in the negative pressure mode.  Instructions for quantitative fit testing are contained the ES&H Section's IH Manual (Chapter 5.1).  If exposure is estimated to be below 1/2 the Fermilab prescribed exposure limit, qualitative fit testing may be performed.

 

b.      Fit testing shall be repeated annually or whenever significant facial changes may affect the facepiece seal (e.g., facial scarring, cosmetic surgery, dental changes, surgery, obvious changes in body weight, etc.).

 

c.      Fit testing shall not be performed and required, tight-fitting respiratory protective equipment shall not be issued if facial hair comes between the sealing surface of the facepiece and the face or if facial hair interferes with valve function.

 

d.      When a respirator user must wear corrective lenses, a protective spectacle or goggle, a face shield, a welding helmet, or other eye and face protective devices, the item shall be fitted to provide good vision and shall be worn in such a manner as not to interfere with the seal of the respirator.

 

e.      Spectacles with straps or temple bars that pass through the sealing surface of either negative or positive pressure, tight fitting, full facepiece respirators shall not be used, unless 1) the device is specifically designed for that purpose and 2) the individual successfully passes the fit test while wearing the device.

 

f.       Contact lenses may be worn with respirators, provided the individual has previously demonstrated that he or she has had successful experience wearing contact lenses.

 

7.      Maintenance

 

Respiratory protection devices must be maintained to retain their original effectiveness.

 

a.             All reusable respirators must be routinely inspected before and after each use. See inspection checklist for reusable respirators, page 17.

 

b.      Self-contained breathing apparatus and emergency escape respirators shall be at least inspected monthly and before and after use.  Air cylinders shall be fully charged according to the manufacturer's instructions.  It shall be determined through inspection that the regulator and warning devices function properly.  There must be a log kept of all monthly inspections.

 

c.      Clean and disinfect each reusable respirator after each use.  The ES&H Section stocks materials for cleaning and disinfecting respiratory protection equipment.  See page 26 for the OSHA Respirator Cleaning Procedures (Appendix B-2, 1910.134).

d.      Properly store reusable respirators.  Following inspection, cleaning, and necessary repair, respirators shall be stored to protect against dust, sunlight, heat, extreme cold, excessive moisture, or damaging chemicals.  Respirators shall be placed in resealable plastic bags for storage.  Respirators should not be stored in such places as lockers or toolboxes unless they are in carrying cases or cartons.  Respirators should be packed or stored so that the facepiece and exhalation valves rest in a normal position and function will not be impaired by the elastomer setting in an abnormal position.

 

e.      Disposable respirators should be disposed of after one day of use, or more frequently, if necessary.

 

8.         Inspection Procedures

 

a.         General

 

            The OSHA Standard requires a respirator inspection include a check of tightness of connections, facepiece, headbands, valves, tubes, filters or cartridges.  Further, all rubber and elastomer parts of respirators must be inspected for pliability and signs of deterioration.

 

b.         Air-Purifying Respirator Inspection

 

The following items are to be examined during the inspection:

 

Examine the facepiece for:

 

·        Excessive dirt.

·        Cracks, tears, holes, or distortion from improper storage.

·        Inflexibility of rubber facepiece (stretch and massage to restore flexibility).

·        Cracked or badly scratched lenses in full facepieces.

·        Incorrectly mounted full facepiece lenses or broken or missing mounting clips.

·        Cracked or broken air-purifying element holder(s).

·        Badly worn threads or missing gasket(s).

           

Examine the headstraps or head harness for:

 

·        Breaks.

·        Loss of elasticity.

·        Broken or malfunctioning buckles and attachments.

·        Excessively worn serration on head harness, which might permit slippage.

 

Examine the exhalation valve for the following after removing its cover:

 

·        Blockage.

·        Foreign material, such as detergent residue, dust particles or human hair under the valve seat.

·        Cracks, tears or distortion in the valve material.

·        Improper insertion of the valve body in the facepiece.

·        Cracks, breaks or chips in the valve body, particularly in the sealing surface.

·        Missing or defective valve cover.

·        Improper installation of the valve in the valve body.

 

Examine the air-purifying elements for:

 

·        Incorrect filter, cartridge or canister for the hazard.

·        Incorrect installation, loose connections, missing or worn gaskets, or cross‑threading in holder.

·        Expired shelf-life date on the cartridge or canister.

·        Cracks or dents in the outside case of the filter, cartridge or canister, indicated by the absence of sealing material, tape, foil, etc., over the inlet.

 

If the device has a corrugated breathing tube, examine it for:

 

·        Broken or missing end connectors.

·        Missing or loose hose clamps.

·        Deterioration, determined by stretching the tube and looking for cracks.

 

c.         Atmosphere-Supplying Respirator Inspection

 

If the device has a tight fitting facepiece, the wearer is to follow the procedures outlined above for air-purifying respirators, except those pertaining to the air-purifying elements.  Additionally, the wearer shall check:

·        Integrity and condition of air supply lines and hoses, including attachment and end fittings.

·        Tightness of connections.

·        Correct operation and condition of all regulators and valves.

·        All fittings and connections to ensure no deviations from design specifications have been made.

·        Breathing air couplings are incompatible with outlets of non-respirable air or other gas systems.

If the device is a hood, helmet, blouse, or full suit, the wearer shall use the following inspection procedure.

 

·        Examine the hood, blouse or full suit for rips and tears, seam integrity, etc.

·        Examine the protective headgear, if required, for general condition with emphasis on the suspension inside the headgear.

·        Examine the protective faceshield, if any, for cracks or breaks or impaired vision due to rebounding abrasive particles.

·        Make sure the protective screen is intact and secured correctly over the faceshield or abrasive blasting hoods and blouses.

 

d.         Air-Line System Inspection

 

Inspection of the airline systems is to include the following checks:

 

·        Intake area situated to ensure the quality of intake air cannot be jeopardized.

·        Calibration and function of alarm systems - CO, high temperature, low air pressure, etc.

·        Operating pressure to determine if the system is within normal range.

·        All air filters on air system.

·        Inspection tag is at compressor.

 

Maintenance and replacement or refurbishment of the compressor and associated parts is to be performed by trained personnel following manufacturer's instructions and recommendations.  Breathing air must meet Grade D specifications as described in the Compressed Gas Association Commodity Specification G-7.1-1989 (oxygen content of 19.5-23.5% condensed hydrocarbons of 5 mg/M3 of air or less, carbon monoxide of 10 ppm or less and carbon dioxide of 1000 ppm or less).  The dew point of air is to be -10° F below the ambient temperature.

 

e.         Self-Contained Breathing Apparatus Inspection

 

1)         General

All inspections are to be conducted by qualified persons.  Air from the respective self-contained breathing apparatus shall not be used for performing tests requiring air consumption.  The person performing the inspection must provide an auxiliary air supply.  Whenever practical, defects should be corrected in the field.  If the unit must be removed from service, it will be the responsibility of the person making the inspection to replace the unit.

 

 

2)         Facepieces

The facepieces of self-contained breathing apparatus should be checked using procedures outlined under air-purifying respirators.

 

3)         Accessories

The manufacturer’s instructions are to be followed which generally include the following:

 

·        Hose connectors, hoses, head harnesses, backpack components; and gauges should be inspected for bulges, wrinkles, or tears.

·        Alarms should be checked by closing the air valve and slowly bleeding excess pressure from the regulator by breathing down the remaining air.

·        The air cylinder should be checked to determine whether it is filled to 90% of capacity and the valve is in closed position.  The hydrostatic test date should be checked for expiration and the cylinder examined for damage, corrosion, chipping, or cracking and air tightness.

·        The regulator checked by opening the cylinder valve, donning the facepiece with the unit in the positive pressure mode and inhaling and exhaling.  The regulator pressure is to be compared to the cylinder pressure and a positive pressure observed in the mask.

·        The operation of the reducing valve and the bypass valve of the regulator should be tested.

·        Check the diaphragm by gently inhaling through the regulator outlet and hold for ten seconds.  Negative pressure is to be maintained.  Gently exhale through the regulator outlet and hold for ten seconds.  Positive pressure should be maintained.

·        Examine all straps, clips and buckles for damage and operability.  All buckles must readily clasp and unclasp and locking mechanism on the cylinder holder must operate properly.  Straps are to be adjusted out fully and are to be untwisted and smooth.

·        Check the regulator housing for damage.  The cover is to be seated and secured.  Ensure the regulator hose coupling is hand tightened to the cylinder valve outlet.

·        Regulator controls are in proper position.

 

f.        Emergency Escape-Only Supplied-Air Respirators Inspection

 

·        Inspect before being carried into the workplace.

·        Examine the plastic hood for cracks or discoloration.

·        Check the gauge for adequate pressure.  The pressure gauge should read full (within the green (full) zone).

REFERENCES

 

American Conference of Governmental Industrial Hygienists (ACGIH) - Threshold Limit Values for Chemical Substances and Physical Agents (current version)

 

American National Standards Institute (ANSI) Z88.2 - 1994 Respiratory Protection

 

ANSI/Compressed Gas Association Commodity Specification for Air, G-7.1-1989

 

Department of Transportation 49 CFR part 173 and 178

 

National Institute of Occupational Safety and Health (NIOSH) 42 CFR part 84

 

NIOSH 30 CFR part 11

 

NIOSH Publication 87-116 Guide to Industrial Respiratory Protection

 

Occupational Safety and Health Administration (OSHA) General Industry Standard

29 Code of Federal Regulations (CFR) 1910.134

 

OSHA General Industry Standards 29 CFR 1910.1000

 

OSHA General Industry Standards 29 CFR 1910.1020

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                         Date____________________

 

Medical Surveillance Request for Respiratory Protection Usage

 

Name_______________________________                         I.D.__________________________

 

___          Lab Employee                                                         Division/Section____________________________

 

___          Contractor/Consultant                                            Employer__________________________________

 

___          User/Other                                                              Institution_________________________________

 

 

Respirator Type(s)* (Please Check):

 

___          Self-Contained Breathing Apparatus (SCBA)

 

___          Air-line Respirator Loose-Fitting (ALRLF)

 

___          Air-line Respirator Tight-Fitting (ALRTF)

 

___          Powered Air-Purifying Respirator Loose-Fitting (PAPRLF)

 

___          Powered Air-Purifying Respirator Tight-Fitting (PAPRTF)

 

___          Negative Pressure Air-Purifying Respirator (APR)

 

 

Supplemental Respirator Information:

 

Respirator Use Duration        _______  hours

 

Respirator Use Frequency  (Circle one)  day                         week                        month                      year

 

Description of work being performed  ______________________________________________________________________

 

_________________________________________________________________________________________________________

 

_________________________________________________________________________________________________________

 

Additional Personal Protective Equipment Required __________________________________________________________

 

_________________________________________________________________________________________________________

 

Temperature Extremes ___________________________     Humidity Extremes ______________________________________

 

__________________________________________________                                            ___________________

Supervisor or ES&H Representative                                                                                      Date

 

*The physician or other licensed health care provider shall be shown examples of the various types of respirator protection by the ES&H section.

 

DISTRIBUTION:  Medical                                                                                                                                   Rev. 3/11/1999


Respirator Log Sheet

Year ________

 

Date

Issued To

D/S

Quantity

Description of Use

Respirator Users

Location Used

Appendix D

Given

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Information for Employees Using Respirators When Not Required Under the Standard

 

Appendix D of the Occupational Safety and Health Administration

 Respiratory Protection Standard 29 CFR Parts 1910 and 1926.

 

Respirators are an effective method of protection against designated hazards when properly selected and worn.  Respirator use is encouraged, even when exposures are below the exposure limit, to provide an additional level of comfort and protection for workers.  However, if a respirator is used improperly or not kept clean, the respirator itself can become a hazard to the worker.  Sometimes, workers may wear respirators to avoid exposures to hazards, even if the amount of hazardous substance does not exceed the limits set by OSHA standards.  If your employer provides respirators for your voluntary use, or if you provide your own respirator, you need to take certain precautions to be sure that the respirator itself does not present a hazard.

 

You should do the following:

 

1.     Read and heed all instructions provided by the manufacturer on use, maintenance, cleaning and care, and warnings regarding the respirators limitations.

 

2.     Choose respirators certified for use to protect against the contaminant of concern.  NIOSH, the National Institute for Occupational Safety and Health of the U.S. Department of Health and Human Services, certifies respirators.  A label or statement of certification should appear on the respirator or respirator packaging.  It will tell you what the respirator is designed for and how much it will protect you.

 

3.     Do not wear your respirator into atmospheres containing contaminants for which your respirator is not designed to protect against.  For example, a respirator designed to filter dust particles will not protect you against gases, vapors, or very small solid particles of fumes or smoke.

 

4.     Keep track of your respirators so that you do not mistakenly use someone else’s respirator

 

User Seal Check Procedures

 

Appendix B-1 of the Occupational Safety and Health Administration

 Respiratory Protection Standard 29 CFR Parts 1910 and 1926.

 

 

The individual who uses a tight-fitting respirator is to perform a user seal check to ensure that an adequate seal is achieved each time the respirator is put on.  Either the positive or negative pressure checks listed in this appendix, or the respirator manufacturer’s recommended user seal check method shall be used.  User seal checks are not substitutes for qualitative or quantitative fit tests.

 

 

I.   Facepiece Positive and/or Negative Pressure Checks

    

A.   Positive pressure check

Close off the exhalation valve and exhale gently into the facepiece.  The face fit is considered satisfactory if a slight positive pressure can be built up inside the facepiece without any evidence of outward leakage of air at the seal.  For most respirators this method of leak testing requires the wearer to first remove the exhalation valve cover before closing off the exhalation valve and then carefully replacing it after the test.

 

B.   Negative pressure check

        Close off the inlet opening of the canister or cartridge(s) by covering with the palm of the hand(s) or by replacing the filter seal(s), inhale gently so that the facepiece collapses slightly, and hold the breath for ten seconds.  The design of the inlet opening of some cartridges cannot be effectively covered with the palm of the hand.  The test can be performed by covering the inlet opening of the cartridge with a then latex or nitrile glove.  If the facepiece remains in its slightly collapsed condition and no inward leakage of air is detected, the tightness of the respirator is considered satisfactory.

 

 

II.   Manufacturer’s Recommended User Seal Check Procedures

 

          The respirator manufacturer’s recommended procedures for performing a user seal check may be used instead of the positive and/or negative pressure checks procedures provided that the employer demonstrates that the manufacturer’s procedures are equally effective.

                       

Respirator Cleaning Procedures

 

Appendix B-2 of the Occupational Safety and Health Administration

 Respiratory Protection Standard 29 CFR Parts 1910 and 1926.

 

These procedures are provided for employer use when cleaning respirators.  They are general in nature, and the employer as an alternative may use the cleaning recommendations provided by the manufacturer of the respirators used by their employee, provided such procedures are as effective as those listed here in Appendix B-2.  Equivalent effectiveness simply means that the procedures used must accomplish the objectives set forth in Appendix B-2, i.e., must ensure that the respirator is properly cleaned and disinfected in a manner that prevents damage to the respirator and does not cause harm to the user.

 

I.     Procedures for Cleaning Respirators

 

A.     Remove filters, cartridges, or canisters.  Disassemble facepieces by removing speaking diaphragms, demand and pressure-demand valve assemblies, hoses, or any components recommended by the manufacturer.  Discard or repair any defective parts.

B.     Wash components in warm (43° C[110° F] maximum) water with a mild detergent or with a cleaner recommended by the manufacturer.  A stiff bristle (not wire) brush may be used to facilitate the removal of dirt.

C.     Rinse components thoroughly in clean, warm (43° C[110° F] maximum), preferably running water.  Drain.

D.     When the cleaner used does not contain a disinfecting agent, respirator components should be immersed for two minutes in one of the following:

1.       Hypochlorite solution (50 ppm of chlorine) made by adding approximately one milliliter of laundry bleach to one liter of water at 43° C (110° F);or,

2.       Aqueous solution of iodine (50 ppm iodine) made by adding approximately 0.8 milliliters of tincture of iodine (6-8 grams ammonium and/or potassium iodide/100 cc of 45% alcohol) to one liter of waster at 43° C (110° F); or,

3.       Other commercially available cleansers of equivalent disinfectant quality when used as directed, if their use is recommend or approved by the respirator manufacturer.

E.      Rinse components thoroughly in clean, warm (43° C[110° F] maximum), preferably running water.  Drain.  The importance of thorough rinsing cannot be overemphasized.  Detergents or disinfectants that dry on facepieces may result in dermatitis.  In addition, some disinfectants may cause deterioration or rubber or corrosion of metal parts if not completely removed.

F.      Components should be hand-dried with a clean lint-free cloth or air-dried.

G.     Reassemble facepiece, replacing filters, cartridges, and canisters where necessary.

H.     Test the respirator to ensure that all components work properly.